977861, 977862 & 977863

Photo of 977861, 977862 & 977863 at Clapham Junction

You need to login/register to view a large version of this photo.
More details can be found here.

Vehicles in this photo

The following vehicle(s) appear in this photo.

  • 977861 - Route Learning Unit 930082
  • 977862 - Route Learning Unit 930082
  • 977863 - Route Learning Unit 930082

Photo details

Favourites


Your comments

  • John Atkinson

    15 November 2003, 23:52:46

    Out of use from 10-03. On hand at Selhurst T&RSMD

  • IAN GRAINGER

    28 October 2005, 12:48:45

    Did this unit have the same modifications ie central large window etc at each end?

  • James

    1 February 2007, 22:05:50

    yes it did

  • ian saunders

    13 March 2007, 21:10:33

    was this unit a rebuilt 4cep ?

  • sam burke

    13 March 2007, 21:46:04

    Yes!

  • Anthony Rispoli

    28 May 2007, 00:00:48

    The train was originally 4-CEP unit 1505, the TSO was removed the large centre window fitted and the lights fitted as well. Sadly in 2005 it was removed from Selhurst and was scrapped at Immingham

  • David Deadman

    24 April 2008, 18:51:55

    I was one of the two (lucky) Driver Instructor's on the South Eastern who drove this unit for a whole week when it came over on loan for a week or two from the 'Central Division' as we 'Ole Boys' knew it. We gave it a good run out when I was on it as in one week it travelled on all the routes from London to Gillingham (via Dartford or Sole Street), Strood to Paddock Wood, Tonbridge to Redhill, Tonbridge to Hastings and all around the Kent coast. Each day it would return and be berthed at Victoria Carriage Sidings. I was conducted by a Tonbridge Driver from Tonbridge to Redhill and back also from Tonbridge to Hastings and back as Victoria Drivers did not have this route knowledge. It was a pleasure to drive as it had been converted with a lot of thought going into it, and it was fitted with modern light clusters as seen in the photograph. It was very spacious inside and it was converted from (I believe) one of the prototype CEP's. Can anyone shed some light on this please? We were given written instructions of the correct way to cut in and cut out this unit as it had I believe, a Converter instead of a Motor Gererator and to do things the wrong way round could cause some electrical damage. Was 930082 a conversion done by Selhurst Level 5 Depot again?

    David Deadman. Driver Instructor, Victoria (South Eastern).

  • kev smith

    28 July 2009, 23:11:27

    the conversion was done by selhurst depot in the lifting shops - the level 5 facility was closed by the time this done.

    it was designed as i recall by the boys in stephenson house when derek woolvett ran south central fleet management


Make a comment

You need to login/register to post a comment.
More details can be found here.